EN | It

DPT-MOD

Multifunctional differential pressure transmitters (with air flow measurement and Modbus)

This multifunctional transmitter has been designed for measuring differential pressure, static, volume flow and velocity. DPT-MOD works fine with several different measurement probes such as FloXact™ or pitot tube, and air dampers.

Price:

100.07 126.42  +VAT: 21%

AZ=autozero
D= display
-40c = cold-resist model

Description

DPT-MOD

All the measurements are read and configured via Modbus communication. An extra advantage is that DPT-IO-MOD requires less wiring than the traditional 3-wire transmitters, due to the fact that its multiple devices can be connected on a single serial line. DPT-MOD can also be used with several different measurement probes such as FloXact™ or pitot tube, and air dampers.

DPT-MOD series devices include:

  • Two selectable functions:
    Measure and monitor in-duct volume flow, velocity or differential pressure
      Measure and monitor air flow across centrifugal fans
  • Multiple selectable measurement units:
    Volume flow: m3/s, m3/h, cfm, l/s
      Velocity: m/s, ft/min
      Pressure: Pa, inWC, mmWC, kPa, mbar
  • Modbus communication protocol

 

DPT-MOD series device options offer:

  • AZ (autozero) function for automatic zero-point calibration, eliminating the need for periodic manual autozeroing to ensure long term accuracy

Here you can find the table to customise your order :

Additional information

Models

DPT-MOD-2500, DPT-MOD-7000

Different Configurations

DPT-MOD-2500-D, DPT-MOD-2500-AZ-D, DPT-MOD-2500-D-40C, DPT-MOD-7000-D, DPT-MOD-7000-AZ-D, DPT-MOD-7000-D-40C

Technical details
Communication: RS-485 Modbus (RTU)
Accuracy (from applied pressure): (model 2500) Pressure < 125 Pa = 1 % + ±2 Pa Pressure > 125 Pa = 1 % + ±1 Pa
Accuracy (from applied pressure): (model 7000) Pressure < 125 Pa = 1.5 % + ±2 Pa Pressure > 125 Pa = 1.5 % + ±1 Pa
Zero point calibration: automatic with autozero element (-AZ), by pushbutton or via Modbus
Measuring units: Pressure: Pa, kPa, mbar, inchWC, mmWC, psi Flow: m3/s, m3/hr, cfm, l/s, m/s, ft/min
Measuring element: MEMS, no flow-through
Supply voltage: 24 VAC ±10 % / 24 VDC ±10 %
Power consumption: < 1.3 W
Output signal: via Modbus
Response time: 1.0−20 s, selectable via menu or via Modbus
Operating temperature: -20…+50 °C (with autozero calibration -5...+50 °C) -40…+50 °C (-40C model)
Protection standard: IP54
INSTALLATION_DPT-MOD   PRODUCT DATASHEET