EN | It

PTL

Pressure transmitters for liquids (condensing & non condensing applications)

PTL series pressure transmitters are manufactured for pressure detection in liquids in heating and cooling systems.

Price:

85,89 131,04  +VAT: 21%

A= current output
V= voltage output
Heat= non condensing applications
Cool= condensing applications

Description

PTL

PTL series pressure transmitters are manufactured for pressure detection in liquids in heating and cooling systems.

 PTL-Heat is used for pressure detection in non-condensing applications such as district heating or heat recovery systems, whereas PTL-Cool is designed for extreme conditions where condensation is a common problem. Thanks to two-layer protection for electronics, PTL-Cool is able to resist in case of special and extreme condition and due to this feature, the possible condensation does not harm the product.

 One of the popular applications of  PTL series products is for refrigerants and non-aggressive gases.

PTL-Heat series devices are commonly used in HVAC/R systems for:
• District heating
• Liquid heat exchangers
• Heating substation
• Air compressor systems

PTL-Cool series devices are commonly used in HVAC/R systems for:
• District cooling
• Fan coil units (FCU)
• Chilled beams

 

Here you can find the table to customise your order :

Additional information

Models

PTL-Heat (non condensing applications), PTL-Cool (condensing applications)

Different Configurations

PTL-Heat-4-V (non condensing applications), PTL-Heat-6-V, PTL-Heat-10-V, PTL-Heat-16-V, PTL-Heat-25-V, PTL-Heat-4-A, PTL-Heat-6-A, PTL-Heat-10-A, PTL-Heat-16-A, PTL-Heat-25-A, PTL-Cool-6-V (condensing applications), PTL-Cool-10-V, PTL-Cool-6-A, PTL-Cool-10-A

Technical details PTL-Cool
Accuracy (from FS): ±1.0 %
Supply voltage: 15...24 VDC/VAC
Output signal: 0...10 V or 4...20 mA
Protection standard: IP65, two-layer protection against condensation
Pressure connector: inside thread G1/4”
Ambient temperature: -40...60 °C
Temperature of medium: -40...50 °C
Technical details PTL-Heat
Accuracy (from FS): ±1.0 %
Supply voltage: 15...24 VDC/VAC
Output signal: 0...10 V or 4...20 mA
Protection standard: IP65, one-layer protection
Pressure connector: inside thread G1/4”
Ambient temperature: 0...105 °C, non-condensing
Temperature of medium: 0...125 °C
 
INSTALLATION PTL     PRODUCT DATASHEET PTL

Reviews

There are no reviews yet.

Be the first to review “PTL”